Shipping and clearance cost during the warranty period
Refer to official website policy. Customer bears the shipping cost to the company, the company bears the back shipping cost. Customer bears all clearance cost.
Question 1: If the red light of machine long on
1. Not configured correctly
Solution: Enter the IP background to configure the machine
Precaution: It can be detected through the official group control "show IP" of Ipollo
2. The background configuration is wrong and a valid pool cannot be detected.
Solution: Check whether the mining pool status is "Alive", if it is "Dead", change the effective mining pool address
3. Control board damaged
Solution: Check to see if the indicator light on the control panel is red
Precaution: Normal working green light flashes intermittently
4. The hashboard is damaged
Solution: Through the small hole, you can see that the white light on the chip board is off.
Precaution: Ipollo V series machines have only one main chip board
5. Not working at high temperature
Solution: The fan speed on the main control board page is abnormal, too high or too low. Check whether the fan configuration is adjusted to the maximum speed of 100.
Precaution: If the fan speed is at maximum and the machine is still too hot and does not work, return it to the factory.
Question 2: If the machine keeps Restart
1. The DAG file inside the machine is updated twice a week and will be restarted at that time. This is normal.
Solution: neglect
Precaution: Usually the frequency is once a week. If the frequency is too high, please contact after-sales service.
2. Detected that the hashrate is too low
Solution: Check the log for after-sales help
Precaution: Can seek after-sales help
3. Pool link is unstable
Solution: Change a mining pool address
Precaution: If some mining pool official websites update their addresses, ask customer service for the latest effective address.
4. The network link is unstable
Solution: Check internet speed
5. Voltage is unstable
Solution: Exclude voltage environment
6. High temperature
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
Precaution: The fan speed can be adjusted manually, it is recommended to adjust it to a maximum of 100
Question 3: If the machine keep low hashrate
1. Based on the 24-hour average computing power, instantaneous low computing power is not a reference value.
Solution: Continue observation for at least 24 hours
2. Fluctuation of 10% is normal
Solution: The 10% fluctuation based on the rated model of the machine is normal.
3. The chip itself is defective and the internal circuit is short-circuited.
Solution: Return to factory
Precaution: The white indicator light of the chip does not light up
4. There is a commission on the mining pool side
Solution: Confirm with the mining pool
5. high temperature
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
6. Firmware defects
Solution: Update to latest firmware
Precaution: V series machine firmware download link: https://ipollo.com/pages/w-series-firmware
7. Small currency
Solution: The currency algorithm is not supported or not fully supported
8. Double dig
Solution: The hashrate of dual mining is relatively low
9. The pool does not support
Solution: Replace the pool
10. Algorithm not supported
Solution: not support
11. DAG file does not have enough memory
Solution: not support
12. The network link is unstable
Solution: Check network
13. Voltage is unstable
Solution: Check voltage
Question 4: If the hashrate of machine keep 0
1. Pool error
Solution: Replace the pool
2. Network Error
Solution: Check network
3. The hashboard is damaged
Solution: Return to factory
4. Wrong mode selected
Solution: Select the mode corresponding to the currency
5. Just configured
Solution: The machine has just been configured and it will take 5-6 minutes to generate computing power.
6. Backend configuration error
Solution: Reconfigure
Question 5: If the temperature of the machine is too high
1. Fan damaged
Solution: Replace fan
2. The air outlet is blocked
Solution: Check whether there is any foreign matter in the air outlet
3. Cooling tower damaged
Solution: Symptoms of abnormally high temperature and feeling hot to the touch
Precaution: Need to cut off the power immediately
4. The cooling tower is loose and misaligned
Solution: Disassemble and inspect, re-fix and apply silicone grease
Preacution: It is necessary to cut off the power and shut down the machine immediately, and contact after-sales guidance for disassembly.
5. Improper indoor temperature control
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
6. Dust
Solution: Clean up dust regularly
Precaution: Once a year in normal environment, wind cleaning is recommended
7. Double mining
Solution: Dual mining consumes a lot of power. If it is higher than 20% of the normal single mining power consumption, please contact after-sales service.
Question 6: If the machine's fan error message(fan error)
1. The machine has just been turned on
Solution: You have just opened the configured mining pool and can ignore this display until it is fully operational.
Precaution: It will disappear automatically after running
2. Pool link is unstable
Solution: Replace the pool
Precaution: This is manifested by frequent switching between pools and a high rejection rate.
3. The network link is unstable
Solution: It will cause the reception rate to drop and the fan to continue to go up and down. You need to check the network.
4. Fan damaged
Solution: Replace fan
Question 7: If the power consumption of the machine is too high
1. Power supply damaged
Solution: Replace power supply
Precaution: It can be tested by replacing the power supply of other machines.
2. Wrong input voltage connected
Solution: Exclude site voltage range
3. No adapter installed
Solution: Install adapter
Precaution: It is recommended to install an adapter in the Americas or other areas with different power ranges.
4. Overclocking mode enabled
Solution: Normal
5. Firmware reason
Solution: Some firmware versions will increase the machine's load and cause high power consumption. Consult after-sales service to install the recommended firmware version.
6. Dual mining mode
Solution: Select the corresponding firmware version, or set the fan speed to the maximum
Question 8: If the machine keeps dropping out
1. Pool address error
Solution: Replace the pool
2. URL address reading error
Solution: Check whether the pool prefix is written incorrectly
Precaution: You can try both tcp and ssl
3. Internet speed is unstable
Solution: Check network
4. The pool is unstable
Solution: Replace the pool
5. Not configured
Solution: Backend configuration
6. Chip failure
Solution: Chip failure
7. Wireless network link is unstable
Solution: It is recommended to change to a network cable
Question 9: If the machine fails to boot
1. Power supply
Solution: Replace power supply
2. Power cable
Solution: Replace power cord
3. Adapter damaged
Solution: Replace adapter
Question 10: If the machine's red and green lights are always on
1. The machine has no executable firmware
Solution: Card swipe
Precaution: Swipe card information to seek after-sales service
Question 11: If the mechaine's wireless cannot be set up
1. Need to plug in the Internet cable settings
Solution: When setting up the Ipollo machine wirelessly, you need to plug in the network cable first.
2. When can you unplug the network cable?
Solution: After the wireless configuration is successful, you can unplug it.
3. Does each machine configuration need to plug in the Internet cable? What is the order?
Solution: You need to plug in the network cable and set it up one by one. If one succeeds, unplug it, then plug in the network cable to the next one, continue the configuration, and so on.
4. Invalid
Solution: Check if the antenna is damaged
Question 12: If the IP address is not found when the miner is configured
1. Network reasons
Solution: Check network
2. Not in the same network segment
Solution: Check if there are other routers and need to manually add network segment settings
3. The group control network segment range has not been modified.
Solution: Check whether the network segment is from 1-254. If not, manually modify the network segment in the background settings.
4. VPN turned on
Solution: Turn off VPN
Question 13: Ipollo double digging tutorial
1. Refer to the video tutorial: https://ipollo.com/blogs/news/etc-ethw-ethf-single-mining-and-zil-dual-mining
Question 14: Ipollo V series card swiping tutorial
1. Video tutorial: https://s5-cs-pub-std.oss-ap-southeast 1.aliyuncs.com/attachment_upload/tid82/%E5%8D%A1%E5%88%B7%E5%9B%BA% E4%BB%B6_1653012985745_mploo.mp4
Question 15: Restore default factory settings
1. When the system is not powered on, hold down the Reset button and power on the system. Once the green light starts flashing, you can let go. After flashing 10 times, the system will automatically restart and restore the default factory settings.